Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.170
Filtrar
1.
Med Sci Monit ; 30: e943526, 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38734884

RESUMEN

BACKGROUND A significant number of atrial fibrillation (AF) recurrences occur after initial ablation, often due to pulmonary vein reconnections or triggers from non-pulmonary veins. MATERIAL AND METHODS Patients with paroxysmal AF who underwent radiofrequency catheter ablation for the first time were enrolled. Base on propensity score matching (1: 1 matching), 118 patients were selected for an optimized workflow for the radiofrequency catheter ablation of paroxysmal AF (OWCA) group and a conventional group. Comparative analysis of the acute and 12-month clinical outcomes was conducted. Moreover, an artificial intelligence analytics platform was used to evaluate the quality of pulmonary vein isolation (PVI) circles. RESULTS PVI was successfully achieved in all patients. Incidence of first-pass isolation of bilateral PVI circles was higher (P=0.009) and acute pulmonary vein reconnections was lower (P=0.027) in the OWCA group than conventional group. The OWCA group displayed a significant reduction in the number of fractured points (P<0.001), stacked points (P=0.003), and a greater proportion of cases in which the radiofrequency index achieved the target value (P=0.003). Additionally, the contact force consistently met the force over time criteria (P<0.001) for bilateral PVI circles in the OWCA group, accompanied by a shorter operation time (P=0.017). During the 12-month follow-up period, the OWCA group exhibited a higher atrial arrhythmia-free survival rate following the initial ablation procedure than did the conventional group. CONCLUSIONS The optimized workflow for radiofrequency catheter ablation of paroxysmal AF could play a crucial role in creating higher quality PVI circles. This improvement is reflected in a significantly elevated 12-month atrial arrhythmia-free survival rate.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Flujo de Trabajo , Humanos , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Venas Pulmonares/cirugía , Anciano , Puntaje de Propensión , Recurrencia
2.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38696675

RESUMEN

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Masculino , Femenino , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Persona de Mediana Edad , Resultado del Tratamiento , Anciano , Imagenología Tridimensional , Catéteres Cardíacos , Factores de Tiempo , Diseño de Equipo , Estudios Prospectivos , Recurrencia
3.
Kyobu Geka ; 77(5): 394-398, 2024 May.
Artículo en Japonés | MEDLINE | ID: mdl-38720610

RESUMEN

A 73-year-old woman presented with left anterior chest pain and back pain. Computed tomography (CT) scan showed an anterior mediastinal tumor. It also showed partial anomalous pulmonary venous drainage (left superior pulmonary vein draining into the left brachiocephalic vein), and the tumor was located near the left brachiocephalic vein. The operation was performed through a median sternotomy to resect the thymus and tumor with partial resection of the left upper lobe due to the tumor's adhesion to the left upper lobe. One of the vascular anomalies encountered in adult thoracic surgery is partial anomalous pulmonary venous drainage. It is important to recognize the presence of such an anomaly on imaging and to anticipate the surgical procedure with a preoperative surgical technique.


Asunto(s)
Venas Pulmonares , Timoma , Neoplasias del Timo , Tomografía Computarizada por Rayos X , Humanos , Femenino , Anciano , Venas Pulmonares/anomalías , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Timoma/cirugía , Timoma/diagnóstico por imagen , Timoma/complicaciones , Neoplasias del Timo/cirugía , Neoplasias del Timo/diagnóstico por imagen , Neoplasias del Timo/complicaciones
4.
J Vis Exp ; (206)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38709062

RESUMEN

Radiofrequency (RF) ablation to perform pulmonary vein isolation (PVI) for the treatment of atrial fibrillation involves some risk to collateral structures, including the esophagus. Proactive esophageal cooling using a dedicated device has been granted marketing authorization by the Food and Drug Administration (FDA) to reduce the risk of ablation-related esophageal injury due to RF cardiac ablation procedures, and more recent data also suggest that esophageal cooling may contribute to improved long-term efficacy of treatment. A mechanistic underpinning explaining these findings exists through the quantification of lesion placement contiguity defined as the Continuity Index (CI). Kautzner et al. quantified the CI by the order of lesion placement, such that whenever a lesion is placed non-adjacent to the prior lesion, the CI is incremented by the number of segments the catheter tip has moved over. To facilitate real-time calculation of the CI and encourage further adoption of this instrument, we propose a modification in which the placement of non-adjacent lesions increments the CI by only one unit, avoiding the need to count potentially nebulous markers of atrial segmentation. The objective of this protocol is to describe the methods of calculating the CI both prospectively during real-time PVI cases and retrospectively using recorded case data. A comparison of the results obtained between cases that utilized proactive esophageal cooling and cases that used luminal esophageal temperature (LET) monitoring is then provided.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Esófago , Fibrilación Atrial/cirugía , Esófago/cirugía , Humanos , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Venas Pulmonares/cirugía
5.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38647070

RESUMEN

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Técnicas de Sutura , Humanos , Fibrilación Atrial/cirugía , Femenino , Masculino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estudios Prospectivos , Venas Pulmonares/cirugía , Técnicas de Sutura/efectos adversos , Anciano , Resultado del Tratamiento , Alemania , Factores de Tiempo , Dispositivos de Cierre Vascular , Ambulación Precoz , Técnicas Hemostáticas/instrumentación
6.
J Am Heart Assoc ; 13(9): e034004, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38639381

RESUMEN

BACKGROUND: An epicardial connection (EC) through the intercaval bundle (EC-ICB) between the right pulmonary vein (RPV) and right atrium (RA) is one of the reasons for the need for carina ablation for PV isolation and may reduce the acute and chronic success of PV isolation. We evaluated the intra-atrial activation sequence during RPV pacing after failure of ipsilateral RPV isolation and sought to identify specific conduction patterns in the presence of EC-ICB. METHODS AND RESULTS: This study included 223 consecutive patients who underwent initial catheter ablation of atrial fibrillation. If the RPV was not isolated using circumferential ablation or reconnected during the waiting period, an exit map was created during mid-RPV carina pacing. If the earliest site on the exit map was the RA, the patient was classified into the EC-ICB group. The exit map, intra-atrial activation sequence, and RPV-high RA time were evaluated. First-pass isolation of the RPV was not achieved in 36 patients (16.1%), and 22 patients (9.9%) showed reconnection. Twelve and 28 patients were classified into the EC-ICB and non-EC-ICB groups, respectively, after excluding those with multiple ablation lesion sets or incomplete mapping. The intra-atrial activation sequence showed different patterns between the 2 groups. The RPV-high RA time was significantly shorter in the EC-ICB than in the non-EC-ICB group (69.2±15.2 versus 148.6±51.2 ms; P<0.001), and RPV-high RA time<89.0 ms was highly predictive of the existence of an EC-ICB (sensitivity, 91.7%; specificity, 89.3%). CONCLUSIONS: An EC-ICB can be effectively detected by intra-atrial sequencing during RPV pacing, and an RPV-high RA time of <89.0 ms was highly predictive.


Asunto(s)
Fibrilación Atrial , Estimulación Cardíaca Artificial , Ablación por Catéter , Atrios Cardíacos , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Estimulación Cardíaca Artificial/métodos , Anciano , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Pericardio/cirugía , Pericardio/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Potenciales de Acción , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca/fisiología
7.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584395

RESUMEN

AIMS: A few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND RESULTS: A novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%. CONCLUSION: The PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Estudios Prospectivos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fenómenos Magnéticos , Recurrencia
8.
BMJ Case Rep ; 17(4)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38663900

RESUMEN

A pulmonary venous aneurysm (PVA) is extremely rare. A PVA can be either congenital or acquired. Possible symptoms include thoracic pain, dyspnoea, haemoptysis and palpitations but can also occur asymptomatically. Treatment can be conservative or surgical depending on growth and risk of rupture or development of mitral insufficiency, symptoms and thrombus formation. Only a few cases have been described in the literature. A recent case study and a literature review are described below.


Asunto(s)
Venas Pulmonares , Humanos , Venas Pulmonares/anomalías , Venas Pulmonares/diagnóstico por imagen , Aneurisma/diagnóstico por imagen , Aneurisma/diagnóstico , Aneurisma/complicaciones , Masculino , Tomografía Computarizada por Rayos X , Pulmón/diagnóstico por imagen , Pulmón/patología , Femenino
9.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38624037

RESUMEN

AIMS: Pulmonary vein isolation using cryoablation is effective and safe in patients with atrial fibrillation (AF). Although both obesity and underweight are associated with a higher risk for incident AF, there is limited data on the efficacy and safety following cryoablation according to body mass index (BMI) especially in Asians. METHODS AND RESULTS: Using the Korean Heart Rhythm Society Cryoablation registry, a multicentre registry of 12 tertiary hospitals, we analysed AF recurrence and procedure-related complications after cryoablation by BMI (kg/m2) groups (BMI < 18.5, underweight, UW; 18.5-23, normal, NW; 23-25, overweight, OW; 25-30, obese Ⅰ, OⅠ; ≥30, obese Ⅱ, OⅡ). A total of 2648 patients were included (median age 62.0 years; 76.7% men; 55.6% non-paroxysmal AF). Patients were categorized by BMI groups: 0.9% UW, 18.7% NW, 24.8% OW, 46.1% OI, and 9.4% OII. Underweight patients were the oldest and had least percentage of non-paroxysmal AF (33.3%). During a median follow-up of 1.7 years, atrial arrhythmia recurred in 874 (33.0%) patients (incidence rate, 18.9 per 100 person-years). After multivariable adjustment, the risk of AF recurrence was higher in UW group compared with NW group (adjusted hazard ratio, 95% confidence interval; 2.55, 1.18-5.50, P = 0.02). Procedure-related complications occurred in 123 (4.7%) patients, and the risk was higher for UW patients (odds ratio, 95% confidence interval; 2.90, 0.94-8.99, P = 0.07), mainly due to transient phrenic nerve palsy. CONCLUSION: Underweight patients showed a higher risk of AF recurrence after cryoablation compared with NW patients. Also, careful attention is needed on the occurrence of phrenic nerve palsy in UW patients.


Asunto(s)
Fibrilación Atrial , Índice de Masa Corporal , Criocirugía , Obesidad , Venas Pulmonares , Recurrencia , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , República de Corea/epidemiología , Anciano , Resultado del Tratamiento , Factores de Riesgo , Venas Pulmonares/cirugía , Obesidad/complicaciones , Delgadez/complicaciones , Factores de Tiempo , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
10.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584468

RESUMEN

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Asunto(s)
Fibrilación Atrial , Catéteres Cardíacos , Ablación por Catéter , Venas Pulmonares , Recurrencia , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Diseño de Equipo , Técnicas Electrofisiológicas Cardíacas , Factores de Tiempo , Frecuencia Cardíaca , Potenciales de Acción
11.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38588039

RESUMEN

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Asunto(s)
Fibrilación Atrial , Criocirugía , Traumatismos de los Nervios Periféricos , Nervio Frénico , Venas Pulmonares , Sistema de Registros , Humanos , Nervio Frénico/lesiones , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Venas Pulmonares/cirugía , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Estudios Prospectivos , Incidencia , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/epidemiología , Traumatismos de los Nervios Periféricos/prevención & control , Persona de Mediana Edad , Resultado del Tratamiento , Ablación por Catéter/efectos adversos
12.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38682165

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation. Confirmation of PVI can be challenging due to the presence of far-field electrograms (EGMs) and sometimes requires additional pacing manoeuvres or mapping. This prospective multicentre study assessed the agreement between a previously trained automated algorithm designed to determine vein isolation status with expert opinion in a real-world clinical setting. METHODS AND RESULTS: Consecutive patients scheduled for PVI were recruited at four centres. The ECGenius electrophysiology (EP) recording system (CathVision ApS, Copenhagen, Denmark) was connected in parallel with the existing system in the laboratory. Electrograms from a circular mapping catheter were annotated during sinus rhythm at baseline pre-ablation, time of isolation, and post-ablation. The ground truth for isolation status was based on operator opinion. The algorithm was applied to the collected PV signals off-line and compared with expert opinion. The primary endpoint was a sensitivity and specificity exceeding 80%. Overall, 498 EGMs (248 at baseline and 250 at PVI) with 5473 individual PV beats from 89 patients (32 females, 62 ± 12 years) were analysed. The algorithm performance reached an area under the curve (AUC) of 92% and met the primary study endpoint with a sensitivity and specificity of 86 and 87%, respectively (P = 0.005; P = 0.004). The algorithm had an accuracy rate of 87% in classifying the time of isolation. CONCLUSION: This study validated an automated algorithm using machine learning to assess the isolation status of pulmonary veins in patients undergoing PVI with different ablation modalities. The algorithm reached an AUC of 92%, with both sensitivity and specificity exceeding the primary study endpoints.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Aprendizaje Automático , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Técnicas Electrofisiológicas Cardíacas/métodos , Resultado del Tratamiento , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Potenciales de Acción , Frecuencia Cardíaca , Algoritmos , Procesamiento de Señales Asistido por Computador
13.
BMC Pulm Med ; 24(1): 192, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38644505

RESUMEN

BACKGROUND: Stenosis and obliteration of the pulmonary vein can be developed by multiple diseases and might cause hemoptysis. Traditional therapy including surgical procedure and conservative treatments might be inappropriate choices to manage massive hemoptysis. CASE PRESENTATION: A 64-year-old man, diagnosed with advanced stage IVA lung squamous cell carcinoma, presented with dyspnea and recurrent, massive hemoptysis. An initial contrast-enhanced computed tomography revealed a giant tumor in the left lung hilus and occlusion of the left superior pulmonary vein. Despite immediate selective bronchial artery embolization and simultaneous embolization of an anomalous branch of the internal thoracic artery, the massive hemoptysis continued. Subsequently, embolization of the left superior pulmonary artery was performed, achieving functional pulmonary lobectomy, which successfully treated the hemoptysis without relapse during a six-month follow-up. The patient continues to undergo cancer therapy and remains stable. CONCLUSIONS: This case successfully managed massive hemoptysis associated with lung cancer invasion into the pulmonary vein through functional pulmonary lobectomy via embolization of the corresponding pulmonary artery.


Asunto(s)
Carcinoma de Células Escamosas , Embolización Terapéutica , Hemoptisis , Neoplasias Pulmonares , Arteria Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Hemoptisis/terapia , Hemoptisis/etiología , Masculino , Persona de Mediana Edad , Embolización Terapéutica/métodos , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/terapia , Arteria Pulmonar/diagnóstico por imagen , Carcinoma de Células Escamosas/complicaciones , Carcinoma de Células Escamosas/terapia , Venas Pulmonares/anomalías , Venas Pulmonares/diagnóstico por imagen , Neumonectomía
14.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38652090

RESUMEN

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Tomografía Computarizada Multidetector , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Atrios Cardíacos/cirugía , Atrios Cardíacos/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento , Recurrencia , Frecuencia Cardíaca , Potenciales de Acción
16.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38563835

RESUMEN

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Compuestos Organotiofosforados , Venas Pulmonares , Humanos , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Teorema de Bayes , Estudios Prospectivos , Venas Pulmonares/cirugía , Ablación por Catéter , Cateterismo
18.
Ann Noninvasive Electrocardiol ; 29(3): e13119, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38682420

RESUMEN

BACKGROUND: To avoid causing a thromboembolic event in patients undergoing catheter ablation for atrial fibrillation (AF), patients are treated with oral anticoagulants (OAC) prior to the procedure. Despite being on anticoagulants, some patients develop a left atrial appendage thrombus (LAAT). To exclude the presence of LAAT, transesophageal ultrasound (TEE) is performed in all patients prior to the procedure. We hypothesized continuous treatment with anticoagulants would result in a low prevalence of LAAT, in patients with low CHA2DS2-VASc score. METHOD: Medical records of consecutive patients planned to undergo AF ablation at Lund University Hospital during the years 2018-2020 were reviewed retrospectively. Examination protocols from transesophageal and transthoracic echocardiography were examined for LAAT and spontaneous echo contrast (SEC). Patients with LAAT and SEC were compared to patients without using Mann-Whitney U-test and Pearson Chi-squared analysis to test for correlation. RESULTS: Of 553 patients, three patients (0.54%) had LAAT, and 18 (3.25%) had spontaneous contrast (SEC). Patients with LAAT or SEC had a higher CHA2DS2-VASc score, more often presented in AF at TEE and less often had a normal sized left atrium. CONCLUSION: There is a low prevalence of LAAT and SEC in patients with AF scheduled for pulmonary vein isolation. Patients with SEC or LAAT tend to have paroxysmal AF less often and more often presented in AF at admission. No patients with CHA2DS2-VASc 0, paroxysmal AF, normal sized left atrium and sinus rhythm at TEE were found to have LAAT or SEC.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Ecocardiografía Transesofágica , Venas Pulmonares , Trombosis , Humanos , Ecocardiografía Transesofágica/métodos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Masculino , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Ablación por Catéter/métodos , Estudios Retrospectivos , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Prevalencia , Persona de Mediana Edad , Anciano , Anticoagulantes/uso terapéutico , Cardiopatías/diagnóstico por imagen , Cardiopatías/epidemiología
19.
Medicina (B Aires) ; 84(2): 351-355, 2024.
Artículo en Español | MEDLINE | ID: mdl-38683523

RESUMEN

Paradoxical embolism due to an isolated pulmonary arteriovenous malformation (PAVM) is a rare cause of ischemic stroke. PAVMs are abnormal high-flow connections between pulmonary arteries and veins, diverting deoxygenated blood into the systemic circulation and they represent a less common source of paradoxical embolisms, especially in young individuals. Endovascular embolization is the preferred treatment for clinically significant PAVMs. We present the case of a 34-year-old woman with a left thalamic ischemic stroke. Severe contrast passage was detected in cerebral arteries through transcranial Doppler. Intracardiac ultrasound did not reveal a patent foramen ovale, prompting further investigation with pulmonary CT angiography, confirming the presence of PAVM. The patient underwent successful endovascular treatment. It is essential to consider PAVM in the etiological diagnosis of ischemic stroke, especially in young patients with signs of abnormal right-to-left communication. Periodic follow-up imaging is recommended to assess potential recurrence or changes in PAVM, emphasizing the importance of appropriate management of these malformations.


La embolia paradojal debido a una malformación arteriovenosa pulmonar (MAVP) aislada es una causa infrecuente de accidente cerebrovascular (ACV) isquémico. Las MAVP son conductos anómalos de alta circulación entre arterias y venas pulmonares, desviando sangre desoxigenada hacia la circulación sistémica y representan una fuente menos común de embolias paradojales, especialmente en personas jóvenes. La embolización endovascular es el tratamiento preferido para MAVP clínicamente significativas. Presentamos el caso de una mujer de 34 años con ACV isquémico talámico izquierdo. Se detectó pasaje de burbujas "en cortina" en arterias cerebrales mediante Doppler transcraneal. En ecografía intracardíaca no se encontró foramen oval permeable, motivo por el cual se avanzó con realización de angiotomografía pulmonar, la cual confirmó la presencia de MAVP. La paciente recibió tratamiento endovascular exitoso. Es esencial considerar la MAVP en el diagnóstico etiológico del ACV isquémico, especialmente en pacientes jóvenes con signos de comunicación anormal de derecha a izquierda. Se recomienda un seguimiento periódico mediante imágenes para evaluar la posible recurrencia o cambios en la MAVP, resaltando la importancia del manejo adecuado de estas malformaciones.


Asunto(s)
Malformaciones Arteriovenosas , Embolia Paradójica , Accidente Cerebrovascular Isquémico , Arteria Pulmonar , Arteria Pulmonar/anomalías , Venas Pulmonares , Venas Pulmonares/anomalías , Humanos , Adulto , Femenino , Embolia Paradójica/diagnóstico por imagen , Embolia Paradójica/etiología , Accidente Cerebrovascular Isquémico/etiología , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Venas Pulmonares/diagnóstico por imagen , Malformaciones Arteriovenosas/complicaciones , Malformaciones Arteriovenosas/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Fístula Arteriovenosa/diagnóstico por imagen , Fístula Arteriovenosa/complicaciones , Embolización Terapéutica/métodos
20.
PLoS One ; 19(4): e0300309, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38578781

RESUMEN

Radiofrequency ablation (RFA) using the CARTO 3D mapping system is a common approach for pulmonary vein isolation to treat atrial fibrillation (AF). Linkage between CARTO procedural data and patients' electronical health records (EHR) provides an opportunity to identify the ablation-related parameters that would predict AF recurrence. The objective of this study is to assess the incremental accuracy of RFA procedural data to predict post-ablation AF recurrence using machine learning model. Procedural data generated during RFA procedure were downloaded from CARTONET and linked to deidentified Mercy Health EHR data. Data were divided into train (70%) and test (30%) data for model development and validation. Automate machine learning (AutoML) was used to predict 1 year AF recurrence, defined as a composite of repeat ablation, electrical cardioversion, and AF hospitalization. At first, AutoML model only included Patients' demographic and clinical characteristics. Second, an AutoML model with procedural variables and demographical/clinical variables was developed. Area under receiver operating characteristic curve (AUROC) and net reclassification improvement (NRI) were used to compare model performances using test data. Among 306 patients, 67 (21.9%) patients experienced 1-year AF recurrence. AUROC increased from 0.66 to 0.78 after adding procedural data in the AutoML model based on test data. For patients with AF recurrence, NRI was 32% for model with procedural data. Nine of 10 important predictive features were CARTO procedural data. From CARTO procedural data, patients with lower contact force in right inferior site, long ablation duration, and low number of left inferior and right roof lesions had a higher risk of AF recurrence. Patients with persistent AF were more likely to have AF recurrence. The machine learning model with procedural data better predicted 1-year AF recurrence than the model without procedural data. The model could be used for identification of patients with high risk of AF recurrence post ablation.


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Ablación por Radiofrecuencia , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Factores de Tiempo , Ablación por Catéter/métodos , Recurrencia , Venas Pulmonares/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA